All repair guides

Olympus Pen E-P2

Olympus Pen E-P2 IS Error Repair

Moderate 2 hours 1 step

This is a repair case for an Olympus Pen E-P2 that was displaying an IS error. As is common, the cause of the error was a cracked motor pinion gear in the IS unit, which prevented the mechanism from operating normally. This seems to be a frequent issue in other models as well. I was able to successfully repair it by cutting a small amount from the cracked part of the pinion gear for both the X and Y axes, slightly shaving down the shaft, and then securing it with adhesive. Required Skills • Precision soldering, disassembling and reassembling tiny mechanical parts, and an eccentric personality that enjoys tedious tasks. Required Tools • Precision Phillips screwdriver (#00 recommended) • Precision tweezers • Soldering iron & solder sucker, etc. • Spudger • Screw management mat (FixMat, commercially available magnetic sheet, etc.) Notice • This guide is incomplete and was created based on memory and photos from the time, so I would appreciate it if you could point out any errors. • Repairs involve risks, including the possibility of injury, burns, smoke or fire, and the device ending up in a worse condition as a result of disassembly. Please proceed at your own risk if you choose to try this.

  1. 1

    About Repair Procedures

    • Since an IS error occurred with this unit as well, I checked and repaired the pinion gear.
    • The E-P2 is a sibling model of the E-P1, which was released slightly earlier in the same period, and its specs, internal structure, and teardown procedures are almost identical. *In terms of appearance, the hot shoe is slightly higher, and a connector has been added under the shoe.
    • Therefore, for further information regarding the repair, please refer to the separately created E-P1 guide. Sorry for being lazy.
    • Olympus Pen E-P1 IS Error Repair

To put it back together

To reassemble your device, follow these steps in reverse order.

Open on iFixit

Written by the iFixit community. Follow it at your own risk, and please unplug anything electrical before you open it.